Brought to you by Barnacle Bill's Marine Supply. (856) 785 9455

Thereeleaton
Okay in a previous post I was having fuel issues with my engine. After doing the tests etc I found I needed to replace the VST. I got the new Vst in and installed and engine is still throwing code 94, short at the pump. Pump works fine with 12v jumped to it, and the plug from the EMM is getting the proper voltage according to my meter. I checked the wires from the plug at EMM, wire 26 and 34 to the plug that would connect to VST. All seem good. What gives? Could I have gotten a faulty VST assembly? I’m literally about to give this engine away if this can’t be fixed SOON. Any input is appreciated, thank you! 
Reply
Visit our web site for all your Evinrude E-TEC needs. PDF service manuals are ready to download. Our parts dept is here to get you the correct part. Pre made Gen1 300 hr and Gen2 500hr kits are ready to ship. Get the information to have our shop clean and flow test your E-TEC injectors. www.bbmarinesupply.com Barnacle Bill's Marine Supply (856) 785 9455
Thereeleaton
That fuel pump is designed to run on 12 volts,so you will not damage it by running it with a toggle switch to the battery. You can use the positive post on the starter solenoid to power the switch and the ground lug on the block. Some mechanics have installed a relay  to turn on the 12 volt power to the pump which is activated by the purple "key on" wire in cases where the fuel pump ground control in the EMM has failed.
 
Evinrude stratgey was to use the existing 55 volt system to feed the pump an average of 12 volts by rapidly pulsing the ground side.
Note- rope start models had no 12 volt source to run the pump. Running a 12 volt electric motor by giving it a 55 volt pulse evry 1/4 of a second would average about 12 volts but would shorten the life of the pump. Now speed that on/off cycle up to 2000 times a second and doesn't get 55 volts long enough to hurt it. I don't recall the exact numbers but the software update for the fuel pump control just increased the pulse rate of the pump control to extend pump life.
Appreciate that info. It’s good to know I can rig it up for the time being. I will do that for this trip and then after I might dig into the motor more or do an honest sell to someone who wants to mess with it. 

Funny I connected wires to the old pump and the wires got instant hot and smoked. So I’m wondering if the wires from the EMM to VST did take a hard hit and they burned or got hot enough to melt/cause a short. Has me wanting to dig into it from curiosity but time will tell. Like I said, It seems wires checked ok with meter but it’s hard to really be sure. 
Reply
olypopper
I figured I wouldn’t, however pump seems fine with power connected from battery. Just odd it wont power up from EMM. 
I'm not convinced your EMM is bad.  I wish I had a list of all the bad parts people have unknowingly purchased from Crowley marine and others.  I have no physical proof of this but I think they are selling chinese counterfeit parts.  They have a very high failure rate and offer no warranty for a reason.  I'd be inclined to try one of Rick's aftermarket pumps and see if it magically works afterwards.  
Experience is what you got when you didn't get what you wanted
Reply
Thereeleaton
I'm not convinced your EMM is bad.  I wish I had a list of all the bad parts people have unknowingly purchased from Crowley marine and others.  I have no physical proof of this but I think they are selling chinese counterfeit parts.  They have a very high failure rate and offer no warranty for a reason.  I'd be inclined to try one of Rick's aftermarket pumps and see if it magically works afterwards.  
I’m not quite convinced myself, but it’s still up in the air. Please point me in the direction of these Rick’s after market parts. 
Reply
Crosbyman
oddly  the EMM  does not declare  OPEN FUEL PUMP code 91  when the pump wires are disconnected. .. EMM .stays on SHORTED FUEL PUMP code 94
 
wouldn't this indicate  a possible bad EMM  ...could the fault code 94  be reset   ? 
 
just  to  clear things up even if a constant  shorted pump alarm  94 does not put the engine in safe or shut down.
Feedback helps everyone tell us what you found !
Please! Post engine mdl#  Close your topic with feedback
Canada - 2005 EDPLSOR 75 HP #5107924 E/W Merc 4hp oldy :-)
Reply
Thereeleaton
 I tried to clear the fault but when I do that diagnostics completely shuts down and I have to re open the program on computer. 
Reply
Thereeleaton
So I did a bit more “ testing “ this evening. A bit back I bought the internal HPP for about $30 hoping that was the fix way before I started posting here. I tested the pump with 12v and it worked.
 
So what I did was put pins in the plug from the EMM to the VST. Clipped on wires to the pins and clipped onto the pump. Clicked on the pump test on diagnostics and the pump would not kick on. When I took the negative off the pump a new fault did come up, 91 fuel pump open like mentioned above. Took that as a good sign that it’s now recognizing that. Still can’t get the 94 fault cleared and it’s odd that the EMM won’t send the power. 
 
Still glad I can run some wires and turn the pump on manually and run the engine as nothing is wrong, or rigged. Lol 
Reply
Crosbyman
the EMM does not "send" power  like in  a conventional positive to negative  flow.  Actual power at 55V +  is  always present in the pump ... fed by the 55v buss  
 
all the EMM does is  rapidly switch  a ground referrence  to litteraly  cause current flow in the pump to drive it.   see RICMCD53 post above. 
 
I suspect  the  controllling " ground" wire from the EMM  can no longer be  switched by the control logic  whose function is to  "pulse" the  pump.. 
 
we don't have access to EMM innards  but  the  control wire likely acts as a  "sense wire" to  detect /observe the 55v returning to the EMM . 
 
 no 55v is interpretted as OPEN  FUEL PUMP code 91                     to much current flow and it declares a code 94 SHORTED PUMP 
 
 thankfully neither code sets  the SAFE MODE .... If running the pump does not draw to much amps  then a local hook-up to purple from the key and frame ground should  work  but be cautious  of  noise spikes  on purple disturbing the EMM..... also powered by purple. 
 
 
 the other option is  relay controlled power to the pump has  mentionned above 
 
If symptoms develop  a small  capacitor  across the "new"  pump wires should short out the spikes to limit any sensitivities  in the EMM.    
 
 
 jmho
Feedback helps everyone tell us what you found !
Please! Post engine mdl#  Close your topic with feedback
Canada - 2005 EDPLSOR 75 HP #5107924 E/W Merc 4hp oldy :-)
Reply
Thereeleaton
I was wondering about the amps it would pull when rigged, any recommendations on fuse/relay size? 
Reply
jimh
Based on the information given in this thread, the circuit that operates the electrical motor in the pump seems to be:
 
55-Volt Bus --------> Pump Motor ------->EMM Internal Circuit that is either open or connected to electrical common ("ground").
 
The pump motor is certainly an inductive load. Switching OFF the current that was flowing into an inductive load generally causes a voltage spike. Doing this 2,000-times per second seems like a lot of spikes being generated.
 
Perhaps the difference between the original pump and its motor and the replacement ("Walbro") pump and its motor is the amount of inductance in the motor windings. The greater the inductance in the motor windings the more electrical energy that exists in the magnetic field created by the windings. The more energy in the magnetic field, the greater the voltage spike created when the flow of current is shut off and the field collapses. This could account for why the EMM seems to consider the "Walbro" pump as a short circuit. 
 
One possible workaround: insert a few Ohms of resistance in the circuit to help alleviate the higher current surge.
As of 2024 I am no longer making legacy E-TEC engine EV-Diagnostic cables .

Reply
jimh
THEREELEATON writes
 
I connected wires to the old pump and the wires got instant hot and smoked.
Wow, that sounds like a very high current was flowing. If that same amount of current tried to flow through the EMM when the pump was connected to the wiring on the engine, that amount of current seems likely to be sufficiently high to cause damage in the EMM.
As of 2024 I am no longer making legacy E-TEC engine EV-Diagnostic cables .

Reply
Crosbyman
another method to kill off  spikes from counter EMF  when the magnetic field collapses  is to simply place a  reversed diode  across the  relay power leads 
.
this thechnique  was used in Telco  offices to short out  spurious  relay noise  spikes  kicking back into the central office  common  supply of battery used by other sensitive equipment.
 
see short video on the effectiveness of a reverse diode in killing of  counterEMF spikes
 
 
 capacitor wise to eliminate spurious noise   messing up the EMM .....some may recall this odd case  from the past 
Feedback helps everyone tell us what you found !
Please! Post engine mdl#  Close your topic with feedback
Canada - 2005 EDPLSOR 75 HP #5107924 E/W Merc 4hp oldy :-)
Reply
rickmcd53
On the 25/30hp ETECs the Walbro brand pump was always used. The pump had a clamping diode across the terminals on top of the pump.
Reply
jimh
On the 25/30hp ETECs the Walbro brand pump was always used. The pump had a clamping diode across the terminals on top of the pump.
RICK--thanks for mentioning that the circuit included a shut diode across the DC motor to help suppress reverse-voltage spikes.
As of 2024 I am no longer making legacy E-TEC engine EV-Diagnostic cables .

Reply
Crosbyman
thanks for the info.
Feedback helps everyone tell us what you found !
Please! Post engine mdl#  Close your topic with feedback
Canada - 2005 EDPLSOR 75 HP #5107924 E/W Merc 4hp oldy :-)
Reply
ElderSparky
I recall replacement pumps causing the over current fault. This was due to slightly different characteristics of the new pumps. In some cases, new firmware was released to remedy the fault code. In other instances, the factory support would provide revised code without an official release. 

if you would post the software part number and PCN currently in you EMM, we can determine whether a cure is available. 
Reply
Reply