rometec40
could anybody tell what could i look at when i get this error code i know its a fault on the electric . but from then what can i look at ?? checked all my wiring and its ok . battery is brand new so am a bit stuck . thank you .

Reply
Visit our web site for all your Evinrude E-TEC needs. PDF service manuals are ready to download. Our parts dept is here to get you the correct part. Pre made Gen1 300 hr and Gen2 500hr kits are ready to ship. Get the information to have our shop clean and flow test your E-TEC injectors. www.bbmarinesupply.com Barnacle Bill's Marine Supply (856) 785 9455
Destinationsea
according to the manual of the 75 to 90hp it states as follows
please note 75hp to 90hp i think it would be the same code for your engine but not sure

code 17: 55v circuit below range.
internal sensor and SAFE  :marked  with a very good sign (Activated)
emm led display LED 1:   on ( running) 
dashboard gauge warning:  check engine
time to activate : 1 minute
senor: circuit voltage/resistance/information ; system voltage <45v. engine limited to 1200rpm: perform stator/charging tests.

Hope this helps. But wait for the experts to confirm.
Reply
Huey
Hi, this code on the I-2 relates to the same issue and you will need to do a stator/charging cirucit test, which I doubt you will know how to do. One thing you can do is make sure you do not have wing nuts and the CCA of the battery meets 640 CCA rating.

Cheers,

Huey.
Reply
rometec40
the battery as just been replace and is a optima blue top 75amp with more than 900amp cca
Reply
ylee

Why such a big battery for a 40hp?

2005 alumacraft 165 yukon
2006 40hp e-tec
Reply
rometec40
well first the minimum required is 640cca with a recomended 700 + then you add the lights and instrument i often go fishing at night for squids so hours with the light on . the battery is supposed to be one of the best at least i know it will do is job .
Reply
Reply